1.5460-796 Product Overview

The Woodward 5460-796 belongs to the 505/505E series digital turbine controllers. It is a microprocessor-based control module designed for single-valve steam turbines,
including single extraction/admission systems or split-range actuator configurations.
The controller features a front panel Operator Control Panel (OCP) with a two-line, 24-character display and multi-function keypad, allowing easy on-site configuration and monitoring.
contacts: Mike
+86 18350224834 (WeChat/WhatsApp)
Email:Mike18350224834@gmail.com
2. 5460-796 Technical Specifications and Parameters
| Parameter | Details |
|---|---|
| Power Supply | +24 VDC, approx. 1 A |
| I/O Outputs | Discrete Outputs: 8 Analog Outputs: 6 Actuator Outputs: 2 |
| Display / HMI | Two-line, 24-character LCD, with multi-function keypad |
| Dimensions | Approx. 14 × 11 × 4 in (35.6 × 27.9 × 10.2 cm) |
| Weight | Approx. 9.11 lbs (4.13 kg) |
| Operating Temperature | –4 to +140 °F (–20 to +60 °C) |
| Storage Temperature | –40 to +185 °F (–40 to +85 °C) |
| Humidity Standard | 95% RH at 20-55 °C for 48 hours without damage |
| Protection Class | Typically meets industrial dust and water protection standards |
| Communication Protocol | Supports Modbus, RS-232 / RS-422 serial interfaces |

3. Brand History
Woodward, Inc., founded in 1870 and headquartered in Fort Collins, Colorado, USA, is a global leader in energy control systems. The company has a long history of innovation in turbine control, engine management,
and power generation systems.
Woodward products are widely recognized for their reliability and precision in demanding industrial and power generation applications.
4. Applications in Industrial Automation
The 5460-796 plays a critical role in industrial automation and power generation environments:
- Steam Turbine Control: Manages startup, speed regulation, and extraction/admission control of steam turbines.
- Power Generation Systems: Used in power plants to regulate turbine-driven generators for stable frequency and load management.
- Compressor and Pump Drive Control: Ensures precise speed control for turbine-driven compressors and pumps.
- Process Industry Applications: Applied in chemical plants, refineries, and other industries requiring precise turbine operation.
- Safety and Protection Functions: Includes overspeed protection, critical speed avoidance, actuator travel limits, and event logging for operational safety.

4、 Installation and Update of Drivers
1. Installing Drivers: Typically, the operating system automatically recognizes hardware devices and installs
the corresponding drivers. But in some cases, users may need to manually install the driver. At this point, users
can visit the official website of the hardware device manufacturer to download and install the latest drivers.
2. Updating Drivers: In order to ensure the performance and compatibility of hardware devices, hardware device
manufacturers will regularly release driver updates. Users can check and update drivers through the device manager
of the operating system or the official website of the hardware device manufacturer.
5、 Fault diagnosis and troubleshooting of drives
1. Common symptoms of drive failure: device failure to recognize, device performance degradation, device malfunction, etc.
2. Fault diagnosis method:
a. Check device connection: Ensure that the hardware device is properly connected to the computer.
b. Check drive version: Confirm if the drive is the latest version, if not, try updating the drive.
c. Check operating system compatibility: Ensure that the drive is compatible with the operating system.
d. Check hardware devices: If possible, try connecting hardware devices to another computer to eliminate the
possibility of hardware device failure.
3. Troubleshooting methods:
a. Reinstall drive: Try uninstalling and reinstalling the drive.
b. Roll back the drive: If there are problems after updating the drive, you can try rolling back to the previous version of the drive.
c. Check hardware devices: If you suspect a problem with the hardware device, you can try replacing it or
contact the hardware device manufacturer for technical support.
d. System restore: If the malfunction is related to the operating system, you can try using the system restore function to restore to the previous state
Click to learn more about Woodward”s products
ASML 8658017006 PCB ASSEMBLY BOARD
8 Inch wafer chuck ASML SVG Silicon Valley Group wafer grindingcoati
ASML SERV.502.27172 ACC TEMP SENSOR PCW CONTROL, NEW
ASML 4022.430.0759 Processor PCB Card MCDM 60 5,5 PAS 50002500 Working
HEIDENHAIN RON 886 36000 54S09-CM V9 ASML 4022.636.86111 SEM-I-769=9G21
ASML 859-9623-001 RETICLE SCATTERED LIGHT, QML, M
ASML 4022.428.11160 Velocity Control PCB Card 4022.428.1116 PAS 50002500
ASML 859-9608-001 RETICLE FOCUS GRATING
PRODRIVE EEQDM MK2 6001-1241-9100 ASML 4022.660.88761 PCB-I-E-1453=9
ASML 4022.430.01090 Reticle Table Control PCB Card PAS 50002500 Working
SVG ASML FTC Fluid Temperature Controller Bath Heat Element Noah Precision 2005
1PCS ASML 4022.437.1856 MC2 AB41 PCB (3-month warrantySHIP FedEx)
NEW ASML 4022.640.59951
ASML 8549525002 ADVANCED MICRASCAN III RETICLE FOCUS FLAT MSX, 193
17 NEW SVG 914224-001 Gas, Mini, Right angle, ASML AVIZA, WJ
ASML 854-9507-001 RETICLE APPLICATIONS LINEWIDTH
TESA BP 880 INTERFACE BOX ASML
CYMER 181807A DFC FOCUS MODULE ASML
IH Supply Set ASML 4022 642 24724 CT IH MANSUP Y+ NXT I5
ASML STEPPER PAS2500 FESTO PNEUMATIC BOX III 4022.428.05422 KAY VALVE
Asml 4022.480.6766 Optique Article Svg GLP 7123 3-0078
SVG Silicon Valley Group 879-0427-001 Wafer Handling Robot Rev. A ASML Working







There are no reviews yet.