Woodward 5461-002 Price Discount | In Stock
1.5461-002 Product Overview

The Woodward 5461-002 belongs to the 505/505E series digital turbine controllers. It is a microprocessor-based control module designed for single-valve steam turbines,
including single extraction/admission systems or split-range actuator configurations.
The controller features a front panel Operator Control Panel (OCP) with a two-line, 24-character display and multi-function keypad, allowing easy on-site configuration and monitoring.
2. 5461-002 Technical Specifications and Parameters
| Parameter | Details |
|---|---|
| Power Supply | +24 VDC, approx. 1 A |
| I/O Outputs | Discrete Outputs: 8 Analog Outputs: 6 Actuator Outputs: 2 |
| Display / HMI | Two-line, 24-character LCD, with multi-function keypad |
| Dimensions | Approx. 14 × 11 × 4 in (35.6 × 27.9 × 10.2 cm) |
| Weight | Approx. 9.11 lbs (4.13 kg) |
| Operating Temperature | –4 to +140 °F (–20 to +60 °C) |
| Storage Temperature | –40 to +185 °F (–40 to +85 °C) |
| Humidity Standard | 95% RH at 20-55 °C for 48 hours without damage |
| Protection Class | Typically meets industrial dust and water protection standards |
| Communication Protocol | Supports Modbus, RS-232 / RS-422 serial interfaces |

3. Brand History
Woodward, Inc., founded in 1870 and headquartered in Fort Collins, Colorado, USA, is a global leader in energy control systems. The company has a long history of innovation in turbine control, engine management,
and power generation systems.
Woodward products are widely recognized for their reliability and precision in demanding industrial and power generation applications.
4. Applications in Industrial Automation
The 5461-002 plays a critical role in industrial automation and power generation environments:
- Steam Turbine Control: Manages startup, speed regulation, and extraction/admission control of steam turbines.
- Power Generation Systems: Used in power plants to regulate turbine-driven generators for stable frequency and load management.
- Compressor and Pump Drive Control: Ensures precise speed control for turbine-driven compressors and pumps.
- Process Industry Applications: Applied in chemical plants, refineries, and other industries requiring precise turbine operation.
- Safety and Protection Functions: Includes overspeed protection, critical speed avoidance, actuator travel limits, and event logging for operational safety.

What are the parameters of stepper motor drivers? Common faults and maintenance of stepper motor drivers
What are the parameters of stepper motor drivers
The basic parameters of the stepper motor driver are as follows:
a、 The power supply can be selected according to the power specifications of the stepper motor being driven.
For AC power supply, such as AC80V, 220V mains power can be supplied to the driver through a step-down transformer.
When selecting a transformer, both voltage and current operating parameters must be considered simultaneously.
If the current value is 3A, the apparent power value obtained from the formula 80V × 3A=240VA cannot reach the actual output
capacity of 3A. The calculation result should be multiplied by a coefficient of 1.5 or more,
and a transformer with 220/80V and 400VA or more should be selected as the power input. The power supply of a two-phase
motor is generally 12-48V,
b、 Output current value. The product labeling value is often the peak energy output capability. When selecting, the minimum
should be at least twice the rated current value of the stepper motor.
The gear of the output current is usually manually set by the dip switch on the control panel, such as 0.9A-3A. This is also
an overload protection setting, and the setting value can refer to the working current value of the stepper motor. Generally, there are 8 levels of grading.
c、 Excitation methods: full step, half step, 4-step, 8-step, 16-step, 32-step, 64 step. Half step is actually a 2-level subdivision,
the higher the subdivision level, the smaller the step torque angle, and the lower the motor speed. The control panel of the stepper
driver is also equipped with a subdivision dip switch, and the subdivision values are also set.
Click to learn more about Woodward”s products
ASML 854-9527-001 OPTICAL ASSY ALIGN TOOL qmlm 859-0028-802
ASML 4022.639.86644 Class 3B ( AIGaAs ) 780nm 10mW Solid state Laser Module
ASML 4022.428.1457 TB 2500 T PCB Card PAS 50002500 Wafer Stepper System
SVG 99-46450-01 9200SE SVG ASML 90 track Z-robot, 23074-01-D, 110164
ASML Level Sensor Demodulator PPCA Board
1PCS ASML 4022 268 00750 PCB 90days warranty via DHL or FedEx
ASML 4022 486 1122 Wafer Vacuum Chuck 4022.486.1122
ASML YMCR 4022.640.75531 , 4022.636.35151 , REXROTH R911171945 YS MOTION RACK
POWER-ONE HPM5G2A1C4KB ASML 680-0146-089 D.C. POWER SUPPLY
New Prodrive PAAC 55025 ASSY ASML 4022.471.90851
HEINZINGER TNQ”S 500 POWER SUPPLY ASML PAS 25005000 4022.430.07522
ASML 4022.430.2048 Mains Switch Unit 4022.428.1761.
1PCS NEW 5322 695 15945 ASML 4022 192 91561PCB via DHL or FedEx
ASML 4022.470.78481 N1222A AGILENT N1222-20001 REVB030401 PCB-I-E-1423=9
SVG JDS Uniphase ASML 4022.472.42562 Laser Head 55mW, 532nm YV04 Class 3b
ASML NXT WS DOUBLE NETZER Y RIGHT Surplus 4022.637.38097 SEM-I-500=6B46
ASML 4022.631.6551 1 KV Limited Dry Clampfree WS MK4 Semiconductor
ASML 4022.640.59951
ASML 859-9608-001 RETICLE, SERIES 92, 4X, FOCUS GRATING
ASML 4022.634.14744
PANalytical 402233010044 MPPC Power Supply Driver Unit Philips ASML Working
ASM 1086-431-01 SUSCEPTOR 300MM FLAT H2 SMALL H10







There are no reviews yet.