Woodward 5464-223 Price Discount | In Stock
1.5464-223 Product Overview

The Woodward 5464-223 belongs to the 505/505E series digital turbine controllers. It is a microprocessor-based control module designed for single-valve steam turbines,
including single extraction/admission systems or split-range actuator configurations.
The controller features a front panel Operator Control Panel (OCP) with a two-line, 24-character display and multi-function keypad, allowing easy on-site configuration and monitoring.
contacts: Mike
+86 18350224834 (WeChat/WhatsApp)
Email:Mike18350224834@gmail.com
2. 5464-223 Technical Specifications and Parameters
| Parameter | Details |
|---|---|
| Power Supply | +24 VDC, approx. 1 A |
| I/O Outputs | Discrete Outputs: 8 Analog Outputs: 6 Actuator Outputs: 2 |
| Display / HMI | Two-line, 24-character LCD, with multi-function keypad |
| Dimensions | Approx. 14 × 11 × 4 in (35.6 × 27.9 × 10.2 cm) |
| Weight | Approx. 9.11 lbs (4.13 kg) |
| Operating Temperature | –4 to +140 °F (–20 to +60 °C) |
| Storage Temperature | –40 to +185 °F (–40 to +85 °C) |
| Humidity Standard | 95% RH at 20-55 °C for 48 hours without damage |
| Protection Class | Typically meets industrial dust and water protection standards |
| Communication Protocol | Supports Modbus, RS-232 / RS-422 serial interfaces |

3. Brand History
Woodward, Inc., founded in 1870 and headquartered in Fort Collins, Colorado, USA, is a global leader in energy control systems. The company has a long history of innovation in turbine control, engine management,
and power generation systems.
Woodward products are widely recognized for their reliability and precision in demanding industrial and power generation applications.
4. Applications in Industrial Automation
The 5464-223 plays a critical role in industrial automation and power generation environments:
- Steam Turbine Control: Manages startup, speed regulation, and extraction/admission control of steam turbines.
- Power Generation Systems: Used in power plants to regulate turbine-driven generators for stable frequency and load management.
- Compressor and Pump Drive Control: Ensures precise speed control for turbine-driven compressors and pumps.
- Process Industry Applications: Applied in chemical plants, refineries, and other industries requiring precise turbine operation.
- Safety and Protection Functions: Includes overspeed protection, critical speed avoidance, actuator travel limits, and event logging for operational safety.

Explanation: 1. SRV-CTRL refers to the servo control module of PLC;
2. Take the → pointer as input and the ← pointer as output.
3. The meanings of each signal are as follows:
INH: Prohibit input of pulse commands (prohibited when open circuit);
OZ -: Z-phase output;
OZ+: Z-phase output;
S-RDY: The servo drive is ready;
ALM: Servo drive fault alarm;
COIN: Positioning completed;
SRV-ON: servo drive “on” signal;
COM -: Negative pole of power supply;
COM+: Positive pole of power supply;
PULS1: Command pulse input terminal;
PULS2: Command pulse input terminal;
SIGN1: Command pulse symbol input terminal;
SIGN2: Command pulse symbol input terminal;
Servo Drive Wiring Guide
In the field of industrial control automation, many devices have strict installation specifications. So, in order to avoid usage
risks and eliminate safety hazards, what are the rules for connecting servo drives?
1. It is recommended to use a three-phase isolation transformer for power supply to reduce the possibility of electric shock.
2. It is recommended to use a noise filter for power supply to improve anti-interference ability.
3. Please install a non melting short-circuit circuit breaker to promptly cut off external power in case of driver failure.
4. The grounding wire should be ≥ 2.5m2, as thick as possible, and made into a single point grounding.
The grounding terminal of the servo motor must be connected to the grounding terminal PE of the driver.
5. Connect the shielding layer of the cable correctly.
To prevent interference and misoperation, it is recommended to install a noise filter and pay attention to:
(1) The noise filter, servo drive, and upper controller should be installed as close as possible.
(2) Surge suppressors must be installed in relays, AC contactors, brakes, and other coils.
(3) Power circuit cables and signal lines should not be tied together.
Click to learn more about Woodward”s products
ASML 4022.428.10810 Blades Control PCB Card 4022.428.1081 PAS 50002500
14066 ASML MODULE BOARD SVG MOTION CONTROLLER, PCB 4022.471.6982
Philips 7122 714 1800 Power Distribution PCB Card ASML 4022.430.0336 PAS
ASML 4022.651.46881
4022.631.14024 4022.637.93931
1PCS ASML 4022.456.04391 RT-X6 124427876 (3-month warrantySHIP FedEx)
4022.476.01371 PSU 270V 1.9A 3HE 12TE
SVG ASML 879-0605-001 Micrascan PCW Manifold
ASML Mat: 4022.455.78511 17mW Red Laser Module in original carry case
SVG 99-46450-01 9200SE SVG ASML 90 track Z-robot, 23074-01-D, 110447
Power-One Power Supply 64A 24VDC SPM5D2D2KH SILICON VALLEY GROUP SVG 90S ASML
Philips PG 3301 COM 4A Processor PCB Card ASML 4022.422.7999 PAS 50002500
ASML PAS 2500 5000 STEPPER TESA BOX 2K0023
HEINZINGER TNQ”S 500 POWER SUPPLY ASML PAS 25005000 4022.430.07522
ASML PAS 2500 STEPPER BARCODE READER 4022.430.0053
ASML 4022.636.06373 SHBM SHB MDRC PLC
ASML PHOTO RETICLE HOLDER 4022.431.01061
ASML 854-9501-002 RETICLE, MICRASCAN III, 4X
Asml 4022.480.6766 Ottico Articolo Svg GLP 7123 3-0078
1PCS NEW 5322 695 15945 ASML 4022 192 72180 via DHL or FedEx
ASML STEPPER PAS2500 FESTO PNEUMATIC BOX III 4022.428.05422 KAY VALVE
ASML SERV.453.76801 Height Gauge PurgeHood WS READ







There are no reviews yet.