Woodward 8444-1067 |CPU Module, Origin: United States
1.8444-1067 Product Overview

The Woodward 8444-1067 belongs to the 505/505E series digital turbine controllers. It is a microprocessor-based control module designed for single-valve steam turbines,
including single extraction/admission systems or split-range actuator configurations.
The controller features a front panel Operator Control Panel (OCP) with a two-line, 24-character display and multi-function keypad, allowing easy on-site configuration and monitoring.
contacts: Mike
+86 18350224834 (WeChat/WhatsApp)
Email:Mike18350224834@gmail.com
2. 8444-1067 Technical Specifications and Parameters
| Parameter | Details |
|---|---|
| Power Supply | +24 VDC, approx. 1 A |
| I/O Outputs | Discrete Outputs: 8 Analog Outputs: 6 Actuator Outputs: 2 |
| Display / HMI | Two-line, 24-character LCD, with multi-function keypad |
| Dimensions | Approx. 14 × 11 × 4 in (35.6 × 27.9 × 10.2 cm) |
| Weight | Approx. 9.11 lbs (4.13 kg) |
| Operating Temperature | –4 to +140 °F (–20 to +60 °C) |
| Storage Temperature | –40 to +185 °F (–40 to +85 °C) |
| Humidity Standard | 95% RH at 20-55 °C for 48 hours without damage |
| Protection Class | Typically meets industrial dust and water protection standards |
| Communication Protocol | Supports Modbus, RS-232 / RS-422 serial interfaces |

3. Brand History
Woodward, Inc., founded in 1870 and headquartered in Fort Collins, Colorado, USA, is a global leader in energy control systems. The company has a long history of innovation in turbine control, engine management,
and power generation systems.
Woodward products are widely recognized for their reliability and precision in demanding industrial and power generation applications.
4. Applications in Industrial Automation
The 8444-1067 plays a critical role in industrial automation and power generation environments:
- Steam Turbine Control: Manages startup, speed regulation, and extraction/admission control of steam turbines.
- Power Generation Systems: Used in power plants to regulate turbine-driven generators for stable frequency and load management.
- Compressor and Pump Drive Control: Ensures precise speed control for turbine-driven compressors and pumps.
- Process Industry Applications: Applied in chemical plants, refineries, and other industries requiring precise turbine operation.
- Safety and Protection Functions: Includes overspeed protection, critical speed avoidance, actuator travel limits, and event logging for operational safety.

3、 Overview of PWM Controller
PWM controller is a control strategy that adjusts the duty cycle of pulses to control the average level of the output signal. It controls
the required output by periodically switching the power supply and adjusting the ratio of switching time to off time. PWM controllers are
widely used in application scenarios that require simulation of continuous signals, such as DC motor speed control, LED brightness
adjustment, audio amplifiers, etc.
principle
The principle of PWM controller is to control the voltage and current in the circuit by changing the width of the pulse. In PWM signals,
the high-level duration is longer and the low-level duration is shorter, which changes the power output in the circuit. Specifically, when the
PWM signal is at a high level, the switches
in the circuit will open and current will flow through the load; When the PWM signal is at a low level, the switch will close and the current will
stop flowing. Therefore, by changing the time ratio of the high and low levels of the PWM signal, it is possible to control the voltage and current in the circuit.
application
PWM controllers are commonly used in application scenarios that require simulation of continuous signals, such as DC motor speed control,
LED brightness adjustment, audio amplifiers, etc. In these applications, PWM controllers can accurately control the average level of the output
signal by adjusting the duty cycle of the pulses, thereby achieving precise control of the equipment.
Click to learn more about Woodward”s products
Asml 4022.471.6181 Blu Onda Sistemi DBV44 W2 Installati
ASML PAS 2500 5000 STEPPER OCU OPERATOR CONTROL UNIT
SVG ASML 879-0317-005 Dose Module Filter & Shutter
ASML 879-0362-002 CHUCK,QMLMSXL
ASML 4022.430.2048 Mains Switch Unit 4022.428.1761.
ASML 4022.472.42602 Class 3B ( AIGaAs ) 780nm 10mW Solid state Laser Module
ASML RED LASER Head Refurbished(SE
ASML 300mm SERV.635.17662 WH TSU-CENTRING UNIT MK2 ASSY 4022.474.3687.
wafer chuck ASML SVG Silicon Valley Group wafer grindingcoati
ASML 4022.428.1804 Prealignment Unit PAS 50002500 Wafer Stepper Working
RED 635 ASML 4022.472.42582
RASM0208 ASSY-PROCESS MANIFOLD 150MM -FRONT ASM E2 & E2000 REACTOR ASML
ASML PAS2500 STEPPER WAFER FLAT FINDER MOTOR ASSEMBLY 4022.451.4818.
ASML KAY PNEUMATIC BOX FOR PAS 25005000 300-42621, KMV1945 VALVES
ASML 4022.642.80163 LS UV LM LASER UNI SEM-I-666=9B48
CARL ZEISS REMA Lens Objective ASML PN: 4022.454.32961 in ASML PAS5500250C
ASML MCWC Controller 4022.481.28213
ASML ASM LITHOGRAPHY PAS 5500 WAFER STEPPER SYSTEM SOFTWARE
LASER COUNTER PARTICLE
ASML SHUTTER ENCODER DRIVE PCB FOR PAS 25005000 4022.430.06721
SVG ASML 859-8140-006-A Motor Drive Assembly
ASML 4022.428.11190 Timing Control PCB Card 4022.428.1119 PAS 50002500