Woodward 8580-085 |CPU Module, Origin: United States
1.8580-085 Product Overview

The Woodward 8580-085 belongs to the 505/505E series digital turbine controllers. It is a microprocessor-based control module designed for single-valve steam turbines,
including single extraction/admission systems or split-range actuator configurations.
The controller features a front panel Operator Control Panel (OCP) with a two-line, 24-character display and multi-function keypad, allowing easy on-site configuration and monitoring.
2. 8580-085 Technical Specifications and Parameters
| Parameter | Details |
|---|---|
| Power Supply | +24 VDC, approx. 1 A |
| I/O Outputs | Discrete Outputs: 8 Analog Outputs: 6 Actuator Outputs: 2 |
| Display / HMI | Two-line, 24-character LCD, with multi-function keypad |
| Dimensions | Approx. 14 × 11 × 4 in (35.6 × 27.9 × 10.2 cm) |
| Weight | Approx. 9.11 lbs (4.13 kg) |
| Operating Temperature | –4 to +140 °F (–20 to +60 °C) |
| Storage Temperature | –40 to +185 °F (–40 to +85 °C) |
| Humidity Standard | 95% RH at 20-55 °C for 48 hours without damage |
| Protection Class | Typically meets industrial dust and water protection standards |
| Communication Protocol | Supports Modbus, RS-232 / RS-422 serial interfaces |

3. Brand History
Woodward, Inc., founded in 1870 and headquartered in Fort Collins, Colorado, USA, is a global leader in energy control systems. The company has a long history of innovation in turbine control, engine management,
and power generation systems.
Woodward products are widely recognized for their reliability and precision in demanding industrial and power generation applications.
4. Applications in Industrial Automation
The 8580-085 plays a critical role in industrial automation and power generation environments:
- Steam Turbine Control: Manages startup, speed regulation, and extraction/admission control of steam turbines.
- Power Generation Systems: Used in power plants to regulate turbine-driven generators for stable frequency and load management.
- Compressor and Pump Drive Control: Ensures precise speed control for turbine-driven compressors and pumps.
- Process Industry Applications: Applied in chemical plants, refineries, and other industries requiring precise turbine operation.
- Safety and Protection Functions: Includes overspeed protection, critical speed avoidance, actuator travel limits, and event logging for operational safety.

Servo drive control mode
1. Feedback compensation type open-loop control
The accuracy of open-loop systems is relatively low due to the step error, start stop error, and mechanical system error of servo drives,
which directly affect the positioning accuracy. Compensation type improvement should be adopted, which has the advantages of both open-loop and
closed-loop systems, namely open-loop stability and closed-loop accuracy. It will not cause system oscillation due to resonance frequency, crawling, or
loss of motion of the machine tool. Feedback compensation type open-loop control does not require gap compensation and pitch compensation.
2. Closed-loop control
Due to the inability of open-loop control to meet the requirements of machine tools, the most fundamental way to improve the control accuracy of servo
drives is to adopt closed-loop control. There is not only a predecessor control channel, but also a feedback channel for detecting output. After comparing the command signal
with the feedback signal, a deviation signal is obtained, forming a closed-loop control system with deviation control.
3. Semi closed loop control
For closed-loop control systems, reasonable design can achieve reliable stability and high accuracy, but directly measuring the position signal of the workbench requires
the use of position detection devices with high installation and maintenance requirements, such as gratings, magnetic rulers, or linear induction synchronizers.
By measuring the angular displacement of the transmission shaft or screw, the equivalent feedback signal of the position output can be indirectly obtained. Due to
the fact that the errors caused by this part of the transmission cannot be automatically compensated by the closed-loop system without including the transmission
chain from the rotating shaft to the worktable, the errors caused by this part of the transmission cannot be automatically compensated by the closed-loop system. Therefore,
this closed-loop control system composed of equivalent feedback signals is called a semi closed loop servo drive, and this control method is called a semi closed loop control method.
Click to learn more about Woodward”s products
SVG 99-80266 Station CPU resist coater ASML litho
1PCS STATION 662 ASML 4022 197 52062 69741 90days warranty via DHL or FedEx
ASML YMCR 4022.640.75531 , 4022.636.35151 , REXROTH R911171945 YS MOTION RACK
ASML 4022.436.6467 PCB Circuit Board ASML AT-700S *for repair
ASML PN: 4022.428.1094
ASML 4022.439.86653 IR2-FIR Solid State Laser Module ELEC-I-1743=9C
ASML SERV.436.60994 POWER AMP CONTROLLER BOARD
SVG 99-46450-01 9200SE SVG ASML 90 track Z-robot, 23074-01-D, 112653
FEI COMPANY ASML PN 4022 293 1915 Ion Column Power Supply ASML FGSU
SVG Silicon Valley Group 879-0427-001 Wafer Handling Robot Rev. A ASML Working
ASML Retro Kit PN: 830007261
1PCS ASML 4022 268 00750 PCB 90days warranty via DHL or FedEx #A7
INTEGRATOR BLOCK 100 22
New ASML 4022.634.44761 NXT Dynamic Flex +x pca Still Sealed
ASML CCM REMOTE CONTROL BOX MAXON MOTOR 4022.636.57337 *SEALED*
Philips 172110 Processor PCB Card ASML 9406.217.2110 PAS 50002500 Working
SVG – Silicon Valley Group, Inc 879-8234-007 ASML
ASML MSMR-TM 4022.636.68175 , 4022.476.01361 , 4022.634.41312 , 4022.634.17221
ASML 4022.428.14550 TB 2500 X PCB Card PAS 50002500 Wafer Stepper System
1pc new 4022.472.06963 ASML By DHL or EMS #G1553 xh
ASML STEPPER SUN COMPUTER ULTRA 60 3D 540-4032-03
Philips 7122 714 1200.4 Dig Control PCB Card DICM ASML PAS 50002500







There are no reviews yet.